FIRMWARE RELEASE NOTE ====================== Products affected: AXIS P5544 PTZ Dome Network Camera Release date: 2018-04-18 Release type: Production Firmware version: 5.41.2.6 File name: P5544_5_41_2_6.bin Preceding release: 5.41.2.5 -------------------------------------------------------------------------------- Upgrade instructions ==================== The firmware can be upgraded using Axis Camera Management, HTTP or FTP. Please follow the instructions from the user's manual, the web page at http://www.axis.com/techsup/cam_servers/how_to_upgrade.htm or the file named howtoupgrade.txt. NOTE ==================== For latest information about Axis Cybersecurity, see https://www.axis.com/se/sv/support/product-security. Corrections in 5.41.2.6 since 5.41.2.5 ====================================== 5.41.2.6:C01 Corrected critical vulnerability ACV-128401. Corrections in 5.41.2.5 since 5.41.2.4 ====================================== 5.41.2.5:C01 Corrected critical vulnerability ACV-120444. Known Bugs/Limitations ====================== 5.41.2.6:L01 Maximum brightness will not result in a white image. 5.41.2.6:L02 The NTP implementation will not synchronize to NTP servers that signal an alarm condition (clock not synchronized) in its Leap Indicator. 5.41.2.6:L03 After changing the date/time of the camera, the video stream will stop after 60 seconds with an RTSP session time out. It does not matter if the media stream is started before or after the time is changed. Workaround: Reboot the camera after the time has been changed manually or by NTP. 5.41.2.6:L04 There is no boundary check when entering a motion detection window name. If the name is more than 1024 charachters long, the parhand application may restart. 5.41.2.6:L05 If RTSP authentication is switched off, streaming H.264 with QuickTime and other Apple compatible clients will not work as they require authentication of the RTSP, but do not allow HTTP authentication. 5.41.2.6:L06 AXIS Media Control client may stop displaying the H.264 video stream after the PC has been locked. Workaround: Reload the Live View page. 5.41.2.6:L07 Daylight saving time does not work for Iran. 5.41.2.6:L08 Bitmap images have more contrast than the corresponding JPEG images. 5.41.2.6:L09 Color parameter has no effect when pulling RTSP stream with color=0. 5.41.2.6:L10 Stream profile names are limited to alphanumerical characters. 5.41.2.6:L11 Constant bit rate might fluctuate more than 10%. 5.41.2.6:L12 Events triggered at the same time, will by default settings share the same filename. This may result in upload of corrupted image. 5.41.2.6:L13 It is recommended to unmount the SD Card before ejecting it. 5.41.2.6:L14 Check and repair is only available if the file system is ext4. 5.41.2.6:L15 When using action rule resulting in short recordings, it is recommended to extend post-event time. 5.41.2.6:L16 Date modifiers "%m-%d-%Y" are not formatted correctly when used with folder name, SMTP subject and message. 5.41.2.6:L17 When the automatic IR cut filter enables/disables the IR cut filter, it may trigger motion detection. 5.41.2.6:L18 An uploaded audio clip must be less than 1.5MB. 5.41.2.6:L19 To playback Matroska files generated by the camera on a computer, you need to have the configuration file ('.conf') in the same folder as the Matroska file ('.mkv'). For more information see: http://www.axis.com/techsup/software/matroska/files/readme.txt 5.41.2.6:L20 Color parameter has no effect when pulling RTSP stream with color=0. 5.41.2.6:L21 Constant bit rate might fluctuate more than 10%. 5.41.2.6:L22 It is recommended to unmount the SD Card before ejecting it. 5.41.2.6:L23 Check and repair is only available if the file system is ext4. 5.41.2.6:L24 When using action rule resulting in short recordings, it is recommended to extend post-event time. 5.41.2.6:L25 Date modifiers "%m-%d-%Y" are not formatted correctly when used with folder name, SMTP subject and message. 5.41.2.6:L26 When making a snapshot during live view, with framerate and bandwidth values enabled as text overlay, the values are shown as 0 in the snapshot. 5.41.2.6:L27 When using Chrome, Privacy masks page need to be refreshed in order to show added privacy masks in the list. 5.41.2.6:L28 On some Windows 7 PC's IP Utility doesn't show the DUT when using IPv6. 5.41.2.6:L29 Expired or not yet valid client certificates will be uploaded successfully instead of being rejected. 5.41.2.6:L30 DVM Honeywell generates criticals when accessing a camera during the boot sequence. 5.41.2.6:L31 Script error when opening many live views 5.41.2.6:L32 Fixed an issue with an uploaded bitmap overlay which was made partially transparent unconditionally. 5.41.2.6:L33 Automatic IR Cut Filter will not work if Auto Iris is off. 5.41.2.6:L34 Switching Auto Iris off may lead to the IR Cut Filter being enabled/disabled. 5.41.2.6:L35 AMC sometimes crashes at startup on some versions of Internet Explorer. 5.41.2.6:L36 Privacy masks are not visible in overview image. 5.41.2.6:L37 Overlay images are not visible in overview image. 5.41.2.6:L38 VMD only detects motion while in overview. 5.41.2.6:L39 Zoom not supported in overview mode. Application Developer Information ================================= The AXIS VAPIX Application Programming Interface version 3 is supported by the AXIS P5544. For more information, please refer to the AXIS VAPIX HTTP API specification version 3, part of the AXIS VAPIX API, available at www.axis.com. Supported AXIS VAPIX API Image Resolutions for P5544. Resolution Exceptions ========== ========== 1280x720 800x450 480x270 320x180 1024x768 1) 1024x576 1) 800x600 1) 768x576 1) 720x576 1) 704x576 1) 704x480 1) 704x288 1) 704x240 1) 640x480 1) 640x360 1) 480x360 1) 384x288 1) 352x288 1) 352x240 1) 320x240 1) 240x180 1) 192x144 1) 176x144 1) 176x120 1) 160x120 1) 160x90 1) 1) Not visible in web user interface 90/180/270 degress rotation is not supported.