Parameter |
Description |
Range |
Move Speed |
Set the default speed to use for pan and tilt movements. |
1-100 |
Nozzle Position |
Point the camera towards the washer nozzle, select Nozzle position and click Save. This saves the current PT position as the washing position and it enables the washer button on the Live View page. To change the nozzle position, unselect Nozzle position and click save. If the washer button is not available on your camera, the washer can also be triggered with the auxiliary command tt:WashingProcedure. |
true, false |
Washer pump pin |
Select the pin that the washer pump is connected to. |
1-4 |
Washer pump time |
Specify how long the pump should run during a washing procedure. The wiper will start when it is 5 seconds left. |
10-60 |
Washer wiper time |
Specify how long the wiper should run during a washing procedure. |
7-60 |
Wiper Dwell Time |
Runs the wiper continuously for a specified time. Enter a value between 1-60 (seconds) and click Save to set the duration of the wiper sequence and enable the wiper button on the Live View page. The wiper blade will continue to run in order to complete the current sequence even after the set time has run out. |
1-60 |
IO portN direction |
Set the direction of the PT unit IO port pin N. |
Input, Output |
IO portN virtual input |
If the IO portN direction is set as input, this number determines the virtual input that is triggered when input pin changes state. This can be used to trigger other events via the events and actions. 0 means that no virtual input will be changed. |
0-32 |
Illuminator type [IL1|IL2] |
When any illuminator has been mounted on the PT unit, it must be set up here to be controllable from the system. None means no light has been mounted, IR means an infrared illuminator has been mounted and White means a white light illuminator has been mounted. The white lights can be turned on with the auxiliary command tt:LightWL|On and off with tt:LightWL|Off. The IR lights can be turned on with the auxiliary command tt:LightIR|On and off with tt:LightIR|Off |
None, IR, White |
IR synch camera day night switch |
If enabled, the driver will turn on any attached IR illuminators if it detects that the camera has gone into night mode, and turn them off in day mode. |
true, false |
Light sensor controls IR |
If enabled, the driver turns on any attached IR illuminators if it detects that the external light sensor has gone below switch threshold, and turns them off if above. |
true, false |
Light sensor controls WL |
If enabled, the driver turns on any attached white light illuminators if it detects that the external light sensor has gone below switch threshold, and turns them off if above. |
true, false |
Light sensor enabled |
If enabled, the external light sensor attached to the IO port is enabled. See below of trigger levels. |
true, false |
Light sensor switch threshold |
The light level from the light sensor when the Light sensor virtual input is set |
0-8000000 mLux |
Light sensor switch threshold hysteresis |
The extra light level that is required to unset Light sensor virtual input. This can be used to compensate for IR illuminators adding to light level read by the external light sensor. |
0-8000000 mLux |
Light sensor switch time |
Specify minimum time that is required (above and below the threshold) before generating a virtual input change. This can be used to stop the light sensor from switching state unnecessary when transitioning. |
1-3600 seconds |
Light sensor update threshold |
Select this option to update the light sensor switch threshold to the current light sensor value. The parameter will then be reset. |
true, false |
Light sensor virtual input |
Enter the virtual input port number that should be enabled when the light sensor goes below the Light sensor switch level. 0 means that no virtual input port will be triggered. |
0-32 |
Network mode |
Failover (default) will use SFP module port if possible, otherwise it will enable the RJ45 port. Daisy-chain will enable both SFP module port and RJ45 port. |
Failover, Daisy-chain |