FIRMWARE RELEASE NOTES ====================== Products involved: AXIS M5013 PTZ Dome Network Camera AXIS M5014 PTZ Dome Network Camera Release date: 2011-05-16 Release type: Production Firmware version: 5.25 File name: M5013_5_25.bin File size: 20971544 bytes Preceding release: n/a AMC version: 5.9.9.0-1 --------------------------------------------------------------------- UPGRADE INSTRUCTIONS ==================== The firmware can be upgraded using Axis Camera Management 3.0, HTTP or FTP. Please follow the instructions from the user's manual, the web page at http://www.axis.com/techsup/cam_servers/how_to_upgrade.htm or the file named howtoupgrade.txt. RELEASE 5.25 ============ 5.25 is the first official release for AXIS M5013/M5014. Known limitations ================= 5.25:L01 A replayed continuous recording can have a different start time and duration than selected. 5.25:L02 When scheduling recordings with different profiles after each other, disk cleanup can fail and result with a stopped recording. 5.25:L03 Axis products fail test case 6.2.24 in version 1.02.2 of the Onvif Conformance Test tool. This is due to a bug in the test tool and test specification, i.e. the Axis interpretation is correct. 5.25:L04 Unmounting and mounting the SD card can fail when removing and reinserting the SD card. This can be avoided by first disconnect the camera. 5.25:L05 Pan and tilt operation are not available using the T8412 Installation Display. 5.25:L06 The web interface for ACAP Image Test application looks odd compared to the normal webinterface. 5.25:L07 When a PTZ VAPIX call to ptz.cgi is done with several commands in the same request, then correct commands will not execute if requested together with an unsupported command. 5.25:L08 A script error "'thePtzValuesArray[...]' is null or not an object" can sometimes occur in live view. This can cause the video stream to stop. It is uncertain when this happen. 5.25:L09 SNMP Silvercreek test 5.4.0.1 over IPv6 will fail. 5.25:L10 The camera web pages may be unreachable after changing the IP address when the camera has been connected to AXIS Internet Dynamic DNS Service. 5.25:L11 Events are not executed in the order they were added if some events are removed and new created. 5.25:L12 "Cross Line Detection" is misspelled to "Cross Line Direction" in a popup message for other browsers than Internet Explorer. 5.25:L13 Uploading an expired or not yet valid encrypted client certificate in PKCS#12 format for 802.1x will succeed instead of being rejected as it should be. 5.25:L14 It is not possible to access the DUT in secure mode using SSL 2.0 (SSL 3.0 disabled) in Firefox 3. 5.25:L15 While using flicker-free 50Hz or 60Hz exposure control highlight environments will be overexposed. 5.25:L16 Playing a continuous recording for which the oldest parts are currently removed by automatic disk cleanup, will not show a correct start/stop time. 5.25:L17 PTZ framework should restart its internal drivers if they crash. They will instead make the whole framework to restart Application Developer Information ================================= The AXIS VAPIX Application Programming Interface is supported by the AXIS M5013/M5014. The following groups are supported by this product. For more information, please refer to the AXIS VAPIX HTTP API specification version 3, part of the AXIS VAPIX API, available at www.axis.com. Group Exceptions ===== ========== General Image and Video Video status (videostatus.cgi) JPEG buffer request (buffer/command.cgi) Image overlay (call_overlay_.cgi) MPEG-4 Dynamic text overlay (dynamicoverlay.cgi) Privacy Masks (privacymask.cgi) PTZ PTZ driver update (ptzupdate.cgi) PTZ administration (ptzadmin.cgi) Set PTZ parameters (ptzparam.cgi) Motion Detection IP filter Audio Audio data transmit (transmit.cgi) Language handling Local Storage Temperature control Built in templates for dynamic parameters are: Template Group ======== ===== 'event' Event 'ftpaction' Event.E#.Actions 'httpaction' Event.E#.Actions 'hwaction' Event.E#.Actions 'ptzaction' Event.E#.Actions 'ptzsensoraction' Event.E#.Actions 'recordaction' Event.E#.Actions 'smtpaction' Event.E#.Actions 'tcpaction' Event.E#.Actions 'ftp_config' EventServers.FTP 'http_config' EventServers.HTTP 'tcp_config' Eventservers.TCP 'customexposurewindow' ImageSource.I#.Sensor 'motion' Motion 'button' PTZ.Auxiliary.A1.Button 'ptzlocator' PTZ.Locator.L#.Zone 'position' PTZ.Preset.P0.Position 'user_ctlqueue' PTZ.UserCtlQueue 'streamprofile' StreamProfile 'streamcache' StreamCache Supported AXIS VAPIX API Image Resolutions for AXIS M5013/M5014. Resolution Exceptions ========== ========== 1280x720 2) 800x600 800x450 640x480 640x360 480x360 480x270 320x240 320x180 1440x900 1) 2) 1024x768 1) 2) 1024x640 1) 2) 800x500 1) 768x576 1) 720x576 1) 704x576 1) 704x480 1) 704x288 1) 704x240 1) 640x400 1) 480x300 1) 384x288 1) 352x288 1) 352x240 1) 320x200 1) 240x180 1) 240x135 1) 192x144 1) 176x144 1) 176x120 1) 160x120 1) 160x100 1) 160x90 1) 80x50 1) 1) Not visible in web user interface 2) Only available for M5014