FIRMWARE RELEASE NOTE ===================== Products affected: AXIS P3904-R and AXIS P3905-R/-RE Release date: 2016-10-07 Release type: Production Firmware version: 6.40.1 File name: P3904-R_6.40.1.bin Preceding release: 5.80.1.2 -------------------------------------------------------------------------------- Upgrade instructions ==================== Upgrade the firmware with AXIS Camera Management, HTTP, or FTP. Follow the instructions given in the User Manual, at http://www.axis.com/support/tecnical-notes/how-to-upgrade, or howtoupgrade.txt, which is included in the firmware folder. New features in 6.40.1 since 5.80.1.2 ===================================== 6.40.1:F1 If Network Share is setup to use DNS host name as host and if the IP address changes after mount, the host name is resolved to current IP address. 6.40.1:F2 Added support for ONVIF standardised I/O events. 6.40.1:F3 Edge storage recording robustness is improved with an automatic database repair feature. 6.40.1:F4 Max exposure time parameter is now available in the Camera Settings. It can be used in LPR installations when setting Max exposure time shorter than default Max shutter time. 6.40.1:F5 Support for the NTCIP ACAP. 6.40.1:F6 SNMP MIB r/w OID values are saved after reboot. 6.40.1:F7 Improved start-up time. 6.40.1:F8 Removed predefined stream profiles: Quality, HDTV, Balanced, Bandwidth, Mobile. 6.40.1:F9 OpenSSL upgraded to version 1.0.2d. This version also provides support for TLS 1.2. 6.40.1:F10 Corrected behavior for conditional triggers. 6.40.1:F11 Improved handling for networks with small MTU values. 6.40.1:F12 Improved Zipstream using dynamic frame rate. 6.40.1:F13 Improved motion and object tracking engine. 6.40.1:F14 Support for ONVIF Profile G. Corrections in 6.40.1 since 5.80.1.2 ==================================== 6.40.1:C1 Improved performance when triggerdata enabled in plain config and when no motion windows have been created. 6.40.1:C2 /Artpec-4 specific Corrected black image problem due to electrostatic discharge of the image sensor. 6.40.1:C3 It is now possible to a select starting point when playing back a recording while using multicast and H.264. 6.40.1:C4 Improved SD card recording handling. 6.40.1:C5 ONVIF users are now handled when PTZ Control Queue is enabled. 6.40.1:C6 Exposure improvements when enabling custom exposure zones. 6.40.1:C7 It is possible to set the RTPS timeout in the URL specifying the stream. 6.40.1:C8 Fine tuning of IR cut filter switch in automatic mode 6.40.1:C9 Preview window is updated when changing Video Stream settings. 6.40.1:C10 Status LED now flashes red/amber when booting without having a network connection. 6.40.1:C11 Improved robustness for Axis ACAPs. 6.40.1:C12 Improved handling of frequent I/O triggering. 6.40.1:C13 When DST is enabled, export recordings can now be done via web interface. 6.40.1:C14 Access to Zipstream settings is now available to Operators. 6.40.1:C15 PullMessages now follow the ONVIF specification 9.1.2. 6.40.1:C16 Possible to use custom stream profile as default in Live View 6.40.1:C17 From the web gui the rule is now triggered on startevent/"signal raise" and not on condition. 6.40.1:C18 Users with admin permissions can edit ACAP configuration settings. 6.40.1:C19 Camera is reached through HTTPS when NAT traversal is enabled. 6.40.1:C20 Rectified pulsing of the image in very bright environment. 6.40.1:C21 Improved Privacy mask alignment. 6.40.1:C22 Manual triggers for all enabled View Areas are shown. 6.40.1:C23 Improved robustness for Axis ACAPs. 6.40.1:C24 Fixed issue with image switching between black & white and color mode. 6.40.1:C25 Improved response performance of GetCompatibleVideoEncoderConfigurations. 6.40.1:C26 Led pulse button can now be turned on in Internet Explorer. 6.40.1:C27 Corrected image corruption issue seen in corridor format. 6.40.1:C28 Switch to turn off the network traffic LED now works. 6.40.1:C29 Fixed script error when naming a privacy mask with åäö. 6.40.1:C30 Added ACAP support for NV12 format. 6.40.1:C31 Corrected possibility to include SPS (Sequence Parameter Set) and PPS (Picture Parameter Set) in the stream according to ACAP documentation. 6.40.1:C32 Fixed security vulnerability CVE-2015-7547 6.40.1:C33 Fixed issues with stopped events for manual triggered recording. 6.40.1:C34 Date format now displayed correctly in ACM. Known Bugs/Limitations ====================== 6.40.1:L1 Recording streams to SD card with a total bit rate above 12Mbit/sec may cause missing frames/sequences. Supported AXIS VAPIX API Image Resolutions for AXIS P3904-R and AXIS P3905-R/-RE ================================================================================ Resolution Exceptions ========== ========== 1920x1080 3) 1280x960 3) 1280x800 3) 1280x720 1024x768 1024x640 800x600 800x500 800x450 640x480 640x400 640x360 480x360 480x300 480x270 320x240 320x200 320x180 240x180 176x144 160x120 160x100 160x90 1400x1050 1) 3) 1440x900 1) 3) 768x576 1) 720x576 1) 704x576 1) 704x480 1) 704x288 1) 704x240 1) 384x288 1) 352x288 1) 352x240 1) 240x135 1) 192x144 1) 176x120 1) 80x50 1) 1) Not visible in web user interface 3) 1080p 1920x1080 (16:9)