FIRMWARE RELEASE NOTES ====================== Products affected: AXIS Q1931-E PT Mount Release date: 2017-10-12 Release type: Production Firmware version: 6.50.2 File name: Q1931-E_6.50.2.bin Preceding release: 6.50.1 -------------------------------------------------------------------------------- UPGRADE INSTRUCTIONS ==================== The firmware can be upgraded using Axis Camera Management, HTTP or FTP. Please follow the instructions from the user's manual, the web page at http://www.axis.com/techsup/cam_servers/how_to_upgrade.htm or the file named howtoupgrade.txt. Corrections in 6.50.2 since 6.50.1 ==================================== Corrections in 6.50.1.3 since 6.50.1.2 ====================================== 6.50.1.3:C01 Corrected help files to show only supported overlay modifiers for mechanical PTZ cameras. 6.50.1.3:C02 The min/max tilt values set by the user are kept after a restart. 6.50.1.3:C03 Corrected a bug that resulted in 503 Service Unavailable when trying to play a recording from a camera with a specific time range via ONVIF. 6.50.1.3:C04 Corrected a bug that added an additional / in the absolute upload path of an SFTP Recipient when saving the action rule causing it to not work correctly. 6.50.1.3:C05 (Internal) Fixed memory leak in parhand daemon that e.g. parameter handling. 6.50.1.3:C06 Corrected the temperature zone placement when image is rotated. 6.50.1.3:C07 (Internal) Fixed memory leak in wsd daemon that e.g. handles ONVIF requests. 6.50.1.3:C08 Corrected a bug that prevented the camera from auto-correcting its position after a mechanical non-PTZ command movement (moving it by hand). 6.50.1.3:C09 It is now possible to enter up to a 64 characters password when establishing the PTZ Remote Camera Connection from Q6000 -> Q60. Previously it was 16 only. 6.50.1.3:C10 Corrected a bug that let the camera stuck in night mode when the light changes in the scene are huge. 6.50.1.3:C11 Corrected a bug that let the overlay text disappear when a client requests a new video stream. 6.50.1.3:C12 Corrected a bug that let the camera become unresponsive after configuring privacy masks. Valid for M3007 and M3027. 6.50.1.3:C13 Corrected a bug that prevented the user from seeing the ACAP running status and re-added the Main Page link to open a ACAP in the web-interface under Setup -> Applications. 6.50.1.3:C14 Corrected a bug that let the camera send corrupted XML data packages within a stream which caused a VMS to not record video motion detection coming from the camera. 6.50.1.3:C15 The license expiration date of an installed ACAP is now shown correctly again when running http://ip-address/axis-cgi/applications/list.cgi. 6.50.1.3:C16 The correct IPv6 router IP-addresses are now shown correctly in the network interface of the web-interface and in ONVIF responses. 6.50.1.3:C17 Adjusted the system log messages for the NTP daemon to be more specific and highlight that there is a time drift instead of an "adjustment". 6.50.1.3:C18 Corrected an issue that disabled IEEE 802.1x network configuration after updating from firmware 5.40 to 6.50. 6.50.1.3:C19 Corrected an issue that resets the barrel distortion correction settings after updating the camera. 6.50.1.3:C20 Support for day and night level shift. 6.50.1.3:C21 Corrected an issue that delivered E-Mails send from the camera with a wrong time zone in the e-mail header. 6.50.1.3:C22 Corrected an issue that delivered E-Mails send from the camera with a wrong time stamp in the e-mail header. 6.50.1.3:C23 Corrected an issue with FTP recipients configured with a DNS name instead of a static IP-address which caused the FTP recipient test or action rule to fail. 6.50.1.3:C24 Upgrade SSL negotiation in the AVHS client to SSLv23 instead of the deprecated TLSv1. 6.50.1.3:C25 Improved connection handling with Honeywell applications. 6.50.1.3:C26 Updated Apache web server to version 2.4.27 to improve overall minimum cyber security standards. 6.50.1.3:C27 The triple DES cipher is not selected as DEFAULT in the HTTPS settings to increase overall cyber security level. 6.50.1.3:C28 OpenSSL has been updated to version 1.0.2k to increase overall minimum cyber security level. 6.50.1.3:C29 Improved certificate handling. Certificates were previously not usable anymore when updating straight from FW 5.40 to 6.50. 6.50.1.3:C30 Corrected an issue that changed the IDs of certificates to numbers instead of keeping the original name. 6.50.1.3:C31 Corrected zoom compensation issue and improved zoom accuracy. 6.50.1.3:C32 Updated the Portable UPnP SDK to 1.6.22 to increase the overall cyber security level. 6.50.1.3:C33 Corrected an issue that prevented EIS to work when the zoom limit was set to optical only. 6.50.1.3:C34 Corrected zoom compensation issue and improved zoom accuracy. 6.50.1.3:C35 Corrected critical vulnerability ACV-120444. 6.50.1.3:C36 Corrected security vulnerability CVE-2016-2147. 6.50.1.3:C37 Corrected security vulnerability CVE-2016-2148. 6.50.1.3:C38 Corrected an issue that let the camera to become unresponsive in rare occasions when using privacy masks. 6.50.1.3:C39 Corrected an issue that let the camera turn the image upside down in rare occations. Corrections in 6.50.1.2 since 6.50.1.1 ====================================== 6.50.1.2:C01 Fixed a bug that prevented a ONVIF client to connect to the camera via digest authentication. 6.50.1.2:C02 Fixed critical vulnerability ACV-116267. Corrections in 6.50.1.1 since 6.50.1 ==================================== 6.50.1.1:C01 Improved stability for TCP notifications. 6.50.1.1:C02 Improved HTTP image upload stability in unstable networks. 6.50.1.1:C03 Improved camera stability when metadata is used. 6.50.1.1:C04 Optimized privacy mask positioning. 6.50.1.1:C05 Corrected Turkey/Istanbul timezone from GMT+2 to GMT+3. 6.50.1.1:C06 Improved camera stability when TriggerData is used. 6.50.1.1:C07 Improved loading of the web interface in unstable networks. 6.50.1.1:C08 Support for recordings with G711 µ-law audio encoding. 6.50.1.1:C09 Corrected a bug that prevented from saving an action rule with a mail recipient that had SSL enabled. 6.50.1.1:C10 PTZ presetposall returns correct preset name. 6.50.1.1:C11 Fixed a bug that let HTTP notification action rules stop retrying from contacting the receiving server after a failed attempt. 6.50.1.1:C12 Corrected a bug in the event system that prevented the camera from re-sending the SMTP notification every 10 seconds in case the receiving server reported an error. 6.50.1.1:C13 Enable the TX-port in RS485 2W-mode for T99A11. Known Bugs/Limitations ====================== 6.50.1.1:L1 It's recommended to factory default the unit before making a downgrade if needed. 6.50.1.1:L2 Recording streams to SD card with a total bit rate above 12Mbit/sec may cause missing frames/sequences. 6.50.1.1:L3 When changing an active https-certificate, the product needs to be restarted for the new certificate to be applied. 6.50.1.1:L4 Pan limits set using VAPIX are not reflected using ONVIF. Supported AXIS VAPIX API Image Resolutions for AXIS Q1931-E PT Mount ==================================================================== Resolution Exceptions ========== ========== 768x576 720x576 640x512 640x480 480x360 384x288 320x256 320x240 240x180 176x144 160x128 160x120 704x576 1) 704x480 1) 704x288 1) 704x240 1) 352x288 1) 352x240 1) 240x135 1) 192x144 1) 176x120 1) 80x60 1) 1) Not visible in web user interface