FIRMWARE RELEASE NOTE ====================== Products affected: Q7401 Release date: 2020-08-21 Release type: Production Firmware version: 5.51.7 Preceding release: 5.51.6.2 -------------------------------------------------------------------------------- Upgrade instructions ==================== Upgrade the firmware according to the instructions given at https://www.axis.com/ca/en/support/technical-notes/how-to-upgrade or howtoupgrade.txt, which is included in the firmware folder. NOTE ==================== For latest information about Axis Cybersecurity, see https://www.axis.com/se/sv/support/product-security. Corrections in 5.51.7 since 5.51.6.2 ===================================== 5.51.7:C01 Added possibility to retrieve the device Owner Authentication Key (OAK) in the web GUI. Note that this functionality requires that the product have direct access to the internet. 5.51.7:C02 Updated the wpa-supplicant to version 2.9 to increase the overall cybersecurity level. The following cybersecurity vulnerabilities are fixed: CVE-2019-13377 CVE-2019-16275. 5.51.7:C03 Updated OpenSSL to 1.1.1d to increase the overall cybersecurity level. 5.51.7:C04 Added support for TLSv1.2. 5.51.7:C05 Updated the client-side URL transfer library (libcurl) to version 7.53.1 to increase the overall cybersecurity level. Corrections in 5.51.6.2 since 5.51.6.1 ======================================= 5.51.6.2:C01 Corrected an issue that caused admin users other than root not to be allowed to change user account passwords. 5.51.6.2:C02 Added ProxyDispatcherOnly option to the O3C/AVHS client that can control proxy configurations of dispatcher services. 5.51.6.2:C03 Corrected an issue that caused camera to drop network connection when using 5.51.6.1 firmware. 5.51.6.2:C04 Added support for NAS over 2TB. Corrections in 5.51.6.1 since 5.51.6 ===================================== 5.51.6.1:C01 Added “X-Frame-Options: sameorigin” to the HTTP Response Headers in order to increase overall minimum cybersecurity level 5.51.6.1:C02 Updated Turkey (Istanbul) timezone to GMT +3. 5.51.6.1:C03 Improved robustness of the O3C client. Corrections in 5.51.6 since 5.51.5.2 ===================================== 5.51.6:C01 Improved robustness of the O3C client. 5.51.6:C02 Removed the root users default password in factory defaulted firmware. The password of the root user must be set first in order to initialize VAPIX and ONVIF interfaces to allow further configuration. This change only affects products in its factory defaulted state, products that are already deployed in production systems are not affected by this update until factory defaulted. Corrections in 5.51.5.2 since 5.51.5.1 ======================================= 5.51.5.2:C01 Corrected an issue that caused event notifications not been triggered on storage disruption. 5.51.5.2:C02 Improved re-connection behavior to AVHS server. The time between failed connection attempts will now gradually increase until a hard limit is reached. 5.51.5.2:C03 A user with administrator rights can now upload PTZ drivers for those cameras supporting this feature. Note that a factory default will be required to remove the old permissions sets from the firmware. 5.51.5.2:C04 Corrected an issue that caused an overload of the CPU after enabling IP adress filtering. 5.51.5.2:C05 Corrected common vulnerabilities in the Linux kernel to increase overall minimum cyber security level. CVE-2010-2960, CVE-2010-4175. 5.51.5.2:C06 Patched security vulernability CVE-2018-14526 in WPA supplicant to increase overall minimum cyber security level. Corrections in 5.51.5.1 since 5.51.5 ==================================== 5.51.5.1:C01 Corrected an issue that caused the action engine to respawn on scheduled triggered action events. 5.51.5.1:C02 Corrected an issue that caused SD cards to become full and write protected on rare occasions. Corrections in 5.51.5 since 5.50.4.9 ==================================== 5.51.5:C01 Updated R2 GlobalSign Root Certificate to version 20170717. 5.51.5:C02 Corrected an issue that let the camera become unresponsive in rare occasions when connected to an AVHS system. 5.51.5:C03 Corrected critical vulnerability ACV-128401. Known Bugs/Limitations ====================== 5.51.6.1:L1 Recording streams to SD Card with a total bit rate above 12Mbit/sec may cause missing frames/sequences. 5.51.6.1:L2 90 and 270 rotation can cause a drop in frame rate. 5.51.6.1:L3 If the device has ongoing continuous recordings and the device is restarted using the restart option in web interface, the current part of recordings(block) can not be accessed or downloaded through the web interface. 5.51.6.1:L4 AXIS Media Control client may stop displaying the H.264 video stream after the PC has been locked. 5.51.6.1:L5 Live view does not work with QuickTime player using default settings. Workaround: Disable Direct3D acceleration in Quicktime. 5.51.6.1:L6 To avoid corrupt recordings, it is recommended to unmount the SD Card before ejecting it. 5.51.6.1:L7 For actions based on PTZ events, it is not possible to use the #P (PTZ preset name) and #p (PTZ preset number) modifiers in the file names for network share uploads. 5.51.6.1:L8 Video overlay text size is a global setting and can not be set for each stream profile. 5.51.6.1:L9 Private keys need to be in a PKCS#1 format in order to function when installing Certificates. 5.51.6.1:L10 If downgrading to previous firmware version, a factory default is recommended after performing the downgrade. 5.51.6.1:L11 Using control queue with Java Applet may result in wrong queue positions if switching between admin and viewer users. 5.51.6.1:L12 On Windows shares, upload paths for events needs to be created on the share before use. 5.51.6.1:L13 AMC with IE10 does not work when using IPv6. 5.51.6.1:L14 Reboot is necessary after enabling SOCKS. 5.51.6.1:L15 When changing active https-certificate, the device needs to be restarted before it becomes active. 5.51.6.1:L16 Upgrading from firmware 5.40 and prior requires an upgrade of the recordings database. This can take up to five minutes and is conducted on first boot. Make sure to not remove power or SD card during the first five minutes after upgrading the device. Recordings made with firmware earlier than 5.20 will not be readable on the SD Card from firmware 5.40 and onward. Backup important recordings and reformat the SD Card after the firmware upgrade. 5.51.6.1:L17 Time modifiers used in the field "Create folder" is only used upon activation of the rule, hence no new folders are created with the current time during an active rule. To have new folders created with time modifiers you should add them in the "Base filename". 5.51.6.1:L18 Unclear error message when uploading audio clip with already existing name. Supported AXIS VAPIX API Image Resolutions for AXIS Q7401 ========================================================= Resolution Exceptions ========== ========== D1 720x576 2) 720x480 3) 4CIF 704x576 2) 704x480 3) 2CIF 704x288 2) 704x240 3) CIF 352x288 2) 352x240 3) QCIF 176x144 2) 176x120 3) VGA 640x480 1) analyze 1) 1) Not visible in web user interface 2) PAL mode resolution 3) NTSC mode resolution