FIRMWARE RELEASE NOTE ===================== Products affected: AXIS C1004-E Release date: 2017-05-03 Release type: Production Firmware version: 1.30.0 File name: C1004-E_1_30_0.bin Preceding release: 1.25.2.1 -------------------------------------------------------------------------------- Upgrade instructions ==================== Upgrade the firmware with AXIS Camera Management, HTTP, or FTP. Follow the instructions given in the User Manual, at http://www.axis.com/support/tecnical-notes/how-to-upgrade, or howtoupgrade.txt, which is included in the firmware folder. New features in 1.30.0 since 1.25.2.1 ===================================== 1.30.0:F1 Adds possibility to configure the speaker system to use multicast for its internal audio streams. 1.30.0:F2 Possibility to start an audio clip via mediaclip.cgi with filename as alternative to clip number. URL generator to generate and play multiple clips randomly using an infinite repeat, specify files using a *-asterix Filename also allows wildcard (*-asterisk) to be able to describe pattern. example: in Audioclips select "some audio clip". in Configure Audio Clip Link edit the Audio clip section to "some audio clip*.mp3" check Infinite repeats then press Test. this will play all "some audio clips" listet in "Audio Clip List" in a random order infinitive 1.30.0:F3 Possible to adjust volume of an individual audio clip played via mediaclip.cgi 1.30.0:F4 Debug information for the speaker system added in server report 1.30.0:F5 Possible to record audio to SD card via VAPIX Recording API (Edge Storage) 1.30.0:F6 its allowed to store up to 50 audio clips in total. 1.30.0:F7 New audio clips delivered as default in firmware. Necessary to do factory default to get them visible. 1.30.0:F8 If Network Share is setup to use DNS host name as host and if the IP address changes after mount, the host name is resolved to current IP address. 1.30.0:F9 Auto-format an SD card to a specified file system upon insertion. This will allow easy installation of a new SD card that will be formatted automatically to a preselected file system, mounted and then recording will be resumed. 1.30.0:F10 SSH command line interface to the products that may be used for specific support and maintenance activities was introduced in 5.50. SSH is now the only supported protocol to establish a connection and telnet is not supported. SSH is not enabled by default but can be activated by an API. 1.30.0:F11 Secure FTP (SFTP) is now supported for a more secure file transfer method. 1.30.0:F12 Improved PoE section in server report with additional and more detailed information about PoE status and power consumption. 1.30.0:F13 OpenSSL upgraded to version 1.0.2d. This version also provides support for TLS 1.2. 1.30.0:F14 SIP Registration Interval can now be modified to a value between 1 second and 36000 seconds. Default value is 300 seconds. 1.30.0:F15 SIP Accounts can now be enabled and disabled. 1.30.0:F16 Configuring a secondary SIP server (Registrar and PublicDomain) is now supported. If the primary SIP server is down the device will fallback to the secondary server. 1.30.0:F17 The maximum duration for SIP calls can now be configured. 1.30.0:F18 Multiple simultaneous SIP calls are now supported: Up to 6 initiated calls, up to 1 active incoming calls and up to 2 active calls in total. 1.30.0:F19 VoIP configuration and status is now included in the Server report. 1.30.0:F20 It is now possible to configure what audio codecs to use in SIP calls. 1.30.0:F21 added extra audioclips, factory default the unit to access them Known Bugs/Limitations ====================== 1.30.0:L1 Recording audio clips does not take in to account that the flash memory can fill up and thus lacks proper error handling. 1.30.0:L2 An alert is shown in the web-page when trying to start ACAP after the rule engine is restarted: "Could not start application, file verification failed. Check logs for more information." Restart the camera to solve the issue. 1.30.0:L3 Using identical start and stop time for a scheduled event will never trigger an event. 1.30.0:L4 Audio clips shipped with the product has been updated in C1004-E/C2005 R1.25.1, so it is will be necessary to factory default the speaker to get the new clips. 1.30.0:L5 When changing an active https-certificate, the product needs to be restarted for the new certificate to be applied. 1.30.0:L6 Password longer than 64 characters is truncated without notifying the user about it. 1.30.0:L7 Generic "File to large"-message when uploading audio clip to device with no more space. 1.30.0:L8 Sip application skips sending 180 message. Device auto - answers 1.30.0:L9 It is not possible to send both RFC2388 and RFC2976 DTMFs through Asterisk at the same time. This limitation can be avoided by using one of RFC 2388 or RFC 2976. It can also be avoided by using Asterisk to transcode into RFC 2976. 1.30.0:L10 When adding a Action Rule to trigger Speaker test on DTMF the rule is not shown in VoIP overview page. 1.30.0:L11 Not possible to trigger on failed Auto Speaker Test with current Action Engine. 1.30.0:L12 If you are running Axis Audio Player version 0_9 or 0_10 and have play-lists configured you have to upgrade to version 0_11 before upgrading the firmware to version 1.25.2.1 otherwise you are going to loose your play-lists.